Warm air heaters EBA, EBC, EBV
1.4 Specifications types EBC 19-86
Air flow rate at 15 °C
Air flow rate at 50 °C
m
3
/h
1450
1625
2050
2250
2900
3250
4000
4400
4900
5400
5800
6400
8000
8800
Range m 12 16 23 26 28 30 35
Gas flow rate at 15 °C
G 20 20 mbar
G25 mbar
G30/G31 28/37 mbar
m
3
/h
m
3
/h
kg/h
2.22
2.46
1.64
2.96
3.29
2.18
3.70
4.11
2.73
4.76
5.28
3.51
5.82
6.43
4.30
7.40
8.22
5.46
10.00
11.10
7.40
Gas intake Ø 1/2" 3/4"
Flue gas exhaust outlet diameter
80/125 80/125 80/125
Single phase 230 V AC IP42
Sound pressure level At 6 meters in free field dB (A) 43 46 49 51 52 53 55
EBC series heaters are suitable for installation indoors.
They feature a high-capacity low-noise dual-intake
centrifugal fan. This heater has a flange coupling for
straightforward connection to a ducted delivery system.
That way, air can be conveyed to where it is actually
needed inside the environment served. A fan casing with
return air intake grille is standard issue.
7
ECO CALORIA Sp. z o.o.
27-200 Starachowice, ul. Zgodna 2
Tel.: +48 41 274 14 41 fax: +48 41 273 71 47 office@ecocaloria.com www.ecocaloria.com